Cooling Tower Fan Controller & Pump Controller| Cooling Tower Fan Controller & Pump Controller In Rajkot,Gujarat,India | Cooling Tower Fan Controller & Pump Controller In Rajkot | Cooling Tower Fan Controller & Pump Controller In Gujarat | Cooling Tower Fan Controller & Pump Controller In India | +91-9825674684

Cooling Tower Fan Controller & Pump Controller

 

THE COOLING TOWER ENERGY SAVER HELPS YOU SAVE ON YOUR ELECTRICITY BILLS TO THE TUNE OF UPTO 60% WITH A PAYBACK PERIOD OF JUST 30-45 DAYS

 

A sensor based controller that automatically switches the FAN motor situated on top of the Cooling Tower ON/OFF, with respect to the temperature of the water. This temperature is sensed with a 2’ ft. (minimum) long sensor fitted onto the water tank, below the cooling tower.

 

PRINCIPLE OF OPERATION OF COOLING TOWER ENERGY SAVER:

 

A Cooling Tower works on the principle of forced Fan Cooling (Induced Draft). The water in the cooling tower is made to flow with a lot of resistance (thru fiber packs / fills). During that flow the Fan motor sucks the heat over thereby cooling the water to maximum of 1-2 degrees below the external ambient temperature. After the water has cooled to this temperature, the Fan Motor continues to run uselessly, as further cooling of water is not possible. It is at this point the Cooling Tower Energy Saver stops the Fan motor and restarts only after the temperature of water has increased.

 

HOW THE SAVINGS ARE EFFECTED ?

 

The FAN Motor runs for the required time only. The unnecessary running of FAN Motor is thus avoided, thereby saving a lot of ENERGY / POWER & WATER. This results in recurring savings for your company, without affecting the cooling efficiency.

This savings are to the tune of up to 60% whereby you recover the cost of the energy saver in just 30 – 45 days !!!! These savings particularly increased during Night Shifts, Winter Season, when the load on Cooling Tower is less, etc. In Industrial environment our customers have clocked up to 70% of Electricity savings. Please refer the savings chart, for the POWER SAVED WITH ENERGY SAVER.

 

SALIENT FEATURES OF DIGITAL ENERGY SAVER

 

Ø  Completely Automatic operation.

Ø  Continous Digital Display of Actual Water Temperature.

Ø  Individually settable MOTOR ON & MOTOR OFF temperatures (0-80ºC)

(This feature customizes Digital Energy Saver to your System)

Ø  independently settable Hooter (warning) temperature (0 – 80ºC)

(In case the water temperature overshoots, the set Hooter temperature, it gives a warning.)

Ø  Built-in Water Level Controller for 2 levels (upper & lower)

(Connect to your fresh water pump to control water level in your tower water tank)

Ø  MOTOR ON & MOTOR OFF Hour meters provided.

(Hour meters help you to calculate and verify cum monitor the savings)

Ø  Can be connected with Motor of any capacity, with any kind of starter.

Ø  Automatic switch over to MANUAL mode in case of emergency. (By Pass)

Ø  RTD sensor used (200mm length provided as a standard feature)

Ø  Can be fixed with your existing MOTOR & STARTER configuration.

Ø  Sturdy Wall Mounting metal body duly powder coated.

Ø  Temperature Settings & Hour meter Readings kept absolutely simple.

 

Options available:

 

Ø  0.1ºC Display Accuracy (normally provided display accuracy as 1ºC)

Ø  Sensor Length more than 200mm.

SAVINGS CHART (MONTH)

 

MOTOR CAPACITY (KW)

FOR CONTINOUS RUNNING OF MOTOR FOR 24 HOURS FOR 26 DAYS/MONTH

Normal Consumption

(@ Rs. 5/- Unit)

Consumption with Energy Saver @ 50% savings

(@ Rs. 5/- Unit)

Consumption with Energy Saver @ 60% savings

(@ Rs. 5/- Unit)

UNITS

AMOUNT

UNITS

AMOUNT

SAVINGS

UNITS

AMOUNT

SAVINGS

3.7

2309

11,545/-

1154

5,770/-

5,770/-

924

4,620/-

6,925/-

5.5

3432

17,160/-

1716

8,580/-

8,580/-

1373

6,865/-

10,295/-

7.5

4680

23,400/-

2340

11,700/-

11,700/-

1872

9,360/-

14,040/-

11.0

6864

34,320/-

3432

17,160/-

17,160/-

2745

13,725/-

20,595/-

15.0

9360

46,800/-

4680

23,400/-

23,400/-

3744

18,720/-

28,080/-

The Cooling Tower Energy Saver unit is also available with soft starter if needed. The soft starter works  as jerk free starting of fan motor. The Cooling Tower Energy Saver is available in Standard Model and Digital Model with MOTOR ON and MOTOR OFF Hour meter. The details of both the models are given hereunder: